Mission

The Control Room Solutions Task Team's (CRSTT's) mission is to work collectively with other NASPI task teams to advance the use of real-time synchronized measurements for the purpose of improving control room operations and grid reliability. This team will utilize its experience and regional diversity to provide advice, direction, support and guidance to NASPI stakeholders and other organizations involved in the development and implementation of real-time synchronized measurement applications. 

CRSTT Work Plan, updated April 2021 (PDF).

Use case document; Mis-operations with PMU Data Summary Table (PDF).

Videos

NASPI Oscillation Detection and Voltage Stability Workshop, Houston, TX, October 22, 2014; NASPI's YouTube Channel.

List of PMU versus SCADA Video Events Summary Videos (Updated April 2018, rev6).

Meetings

Event Date
Jan 21-22

NASPI Task Team Virtual Meeting
Task Team Meeting

Much of NASPI’s impact is due to the ongoing volunteer work that occurs within its task teams. These teams develop and promulgate best practices while serving as incubators for new ideas and approaches to solve common problems. During quarterly task team meetings, participants will have the...
Event Date
Jan 21 - 22, 2026
Format
Virtual
Contact
naspi@pnnl.gov

Documents

Release Date
Document Subject Area
Event Analysis
CRSTT Use Case
Description
A 69Kv line trip occurred during a storm where the fault was cleared properly by the line protective equipment. Within seconds an area generator trip was observed. When comparing the synchrophasor data it was clear that the unit trip occurred within cycles of the transmission fault indicating the...
Release Date
Description
NYISO System Operators observed transient voltage oscillations in Supervisory Control and Data Acquisition (SCADA) data. The oscillations lasted for three minutes and appeared on many of the western New York 345 kV busses.
Release Date
Document Subject Area
CRSTT Use Case
Description
In 2011, the Dominion System Operator requested a nuclear power plant to reduce its terminal voltage by 3 kV during light load conditions.
Release Date
ERICA Number
NASPI-2016-TR-003
Document Subject Area
Key Phasor Technology Resources
Phase Angle Monitoring
Description
This paper addresses how synchrophasor technology can be used for phase angle monitoring and describes the various synchrophasor-based applications being used by electric utilities and grid operators presently. Uses for phase angle monitoring include: • Wide-area situational awareness and...
Release Date
ERICA Number
NASPI-2015-TR-016
Document Subject Area
Key Phasor Technology Resources
Using Synchrophasor Data for Voltage Stability Assessment
Description
This paper describes certain functional entity roles and responsibilities related to voltage stability monitoring, considers how synchrophasor technology may be used to identify actual or potential voltage stability issues, and describes some of the related commercial applications that are currently...