Skip to main content
Release Date
Document Subject Area
Model Validation
Calibration using synchrophasors
Model Parameter Tuning
Description
NASPI Tracking Number: NASPI-2024-TR-001
Release Date
ERICA Number
PNNL- SA-149900
Document Subject Area
CRSTT Use Case
Description
TRS and PNNL collaborated to develop a Use of Time-Synchronized Measurements in the Real-time Ops Horizon training course (8 CEH). Course Summary: Provide an introduction to synchrophasor technology, describe the value it can provide in the Real-time Ops Horizon, and demonstrate how synchrophasor...
Release Date
ERICA Number
NASPI-2019-TR-003
Document Subject Area
NASPI Basic Synchrophasor Technology Information and Best Practices
Disturbance Detection
Synchrophasor Data and Applications
Description
This paper describes how synchrophasor technology can be used in the Real-time Operations Horizon to determine the origin, nature and severity of disturbances on the electric power system. Specifically, this paper considers how synchrophasor data and their application can be used by System...
Release Date
ERICA Number
PNNL-28218 / NASPI-2018-TT-007
Document Subject Area
NASPI Basic Synchrophasor Technology Information and Best Practices
Data Mining Techniques and Tools
Description
Data mining is the process of turning raw data into useful information. Data mining has been employed in many different data-rich industries, including banking, healthcare, manufacturing, and telecommunications. With the additions of thousands of PMUs to the nation’s power grid, the power systems...
Release Date
ERICA Number
PNNL-28197 / NASPI-2018-TR-008
Document Subject Area
Application Data Requirements
Categorizing PMUs
Description
Phasor measurement units (PMUs) are becoming prevalent on the power system, as is their integration into advanced power system applications. Performance characteristics for the PMU devices are formalized under IEEE Standard C37.118.1-2011 [1]. Formalizing the data requirements for PMU-based...
Release Date
ERICA Number
NASPI-2017-TR-007
Document Subject Area
Oscillation Detection
Oscillation Events
Oscillation Commercial Applications
Description
This paper describes certain functional entity roles and responsibilities related to oscillation detection monitoring, considers how synchrophasor technology may be used to identify actual oscillation events or issues, and describes some of the related commercial applications that are currently...
Release Date
Document Subject Area
Event Analysis
CRSTT Use Case
Description
An ATC Operations Engineer was using synchrophasor data to review fault operations and stumbled across the odd voltage signature shown below from a PMU monitoring one of our 69 Kv substations. One of the three voltage phases would “drift” away from the other two phase voltages and then eventually...
Release Date
Document Subject Area
Event Analysis
CRSTT Use Case
Description
We have observed significant sustained voltage oscillations on the ATC transmission system that were not visible in our SCADA data. These oscillations are normally in the 0.6 – 0.75 Hz range and are lightly damped. They can persist for weeks and then disappear for weeks and even months.
Release Date
ERICA Number
NASPI-2007-TR-007
Document Subject Area
Synchrophasor Measurement Accuracy
Description
November 30, 2007. Prepared by A. P. Meliopoulos, CERTS – Task Force Leader, et al. Digital data acquisition equipment with GPS synchronization adds another dimension to the utilization and application of the data. The technology is young and as such the performance of similar equipment from...
Release Date